Left on after the fire test: how PEAK stopped a shopping centre running its plant all night
After an annual fire test, a Queensland shopping centre's HVAC was left in override and ran overnight. PEAK alerted the contractors automatically and it was fixed in a day.

This is some text inside of a div block.
From 3.5 to 5.5 stars: how a Sydney office lifted its NABERS Indoor Environment rating
After two years at 3.5 stars, a Sydney CBD office reached 5.5 stars for NABERS Indoor Environment. PEAK's comfort alerts and zone data helped the site team put thermal comfort first.

This is some text inside of a div block.
A first 6 star NABERS Energy rating, and a national portfolio that now tracks every office monthly
A national office owner now tracks NABERS across its whole portfolio every month, using CIM's traffic-light risk framework. In the same edition, one of its offices achieved 6 star NABERS Energy for the first time.

This is some text inside of a div block.
Lost, regained, then locked in: a Brisbane office holds its 5 star NABERS Energy rating
A Brisbane CBD office lost its 5 star NABERS Energy rating, won it back by a slim margin, then used monthly rating tracking in PEAK to hold it. The owner was confident enough to rate early.

This is some text inside of a div block.
Frozen for years, invisible on the BMS: how an engineering partner found hidden faults across an arts campus
A US building performance engineering firm put a multi-building arts campus on PEAK. It found VAV boxes frozen for years, equipment the owner did not know it had, and pinpointed a remote failure to the minute.
This is some text inside of a div block.
24/7 HVAC switched off: Illinois high school cuts electricity 35.5% with utility-funded MBCx on PEAK
Every HVAC unit at a 550,000 sq ft high school had run around the clock for years. Aero Performance Group used PEAK to find it, put 21 units back on schedules and verified a 35.5% electricity cut in under five months, at no cost to the district.

This is some text inside of a div block.
Chiller down, BAS dark: how PEAK kept a school's classrooms cool
A new chiller failed at a US high school on the same morning its BAS front-end went dark. PEAK flagged it first thing, and the fix landed before anyone in class noticed.

This is some text inside of a div block.
A London headquarters cuts electricity use by 14% in its first 11 weeks on PEAK
Eleven weeks after PEAK went live, a London corporate headquarters was using 14% less electricity than a year earlier, around £27,900 saved, with the latest fortnight down 23%.

This is some text inside of a div block.
A weather sensor in a riser: how fixing one reading helped cut winter chiller runtime by 88%
The outside air sensor at a Sydney office tower had been installed inside a riser. Fixing it, alongside eight other winter strategies, cut chiller runtime by 88% and business-hours electricity by 12%.

This is some text inside of a div block.
The chiller that would not switch off: two control settings cut winter runtime from 37% to 2.5%
A museum buffer tank was failing to keep the chiller off in winter. PEAK traced the cause to two control settings, and fixing them cut chiller runtime from 37% to 2.5% with no capital spend.

This is some text inside of a div block.
From demo room to plant room: sceptical engineers confirm a £25,000 fault in 98 minutes
A sceptical engineering team put PEAK to the test during their first training session — and confirmed a live £25,053-a-year chilled water valve fault within 98 minutes.
This is some text inside of a div block.
DLP review of student facility uncovers key system gaps before handover
As a student accomodation building entered its defect liability period (DLP), the site team needed clear visibility into BMS contractor deliverables.