PEAK Platform integrations

How PEAK connects to your building

PEAK reads the building systems you already have. No controls replacement, no new field devices, and no change to how your BMS runs the plant.
PEAKby CIMBACnet/IPNative readBACnet MS/TPRouted to IPVendor APIWhere BACnet is closedCSV extractScheduled exportMetersUtility and sub-metersIoT and weatherSensors and conditions
600+
buildings connected
11
countries across 4 continents
4
ways to connect an existing BMS
In short

PEAK integrates with any building management system that exposes BACnet/IP, routed BACnet MS/TP, a vendor API or scheduled CSV exports, without a rip-and-replace of your existing controls.

PEAK only reads. It does not command plant, does not alter your control strategy, and requires no new field devices. The only hardware on site is the BACER collector, which reads the network.

Connection paths

Four ways PEAK reads your BMS

PEAK is BMS-agnostic. It reads your existing building management system, meters and sub-meters, then analyses that data independently of the system that produced it. Every site connects through one of these four paths.

Preferred

BACnet/IP

The BACER collector reads BACnet/IP traffic directly on the BMS network. Highest fidelity and lowest lag. Used at any site where BACnet/IP is exposed.

BACnet MS/TP routed to IP

MS/TP trunks are routed to BACnet/IP through a BACnet router, and BACER reads the IP side. Routers commonly already in place include the Tridium JACE, Johnson Controls SBH, Contemporary Controls BASrouter and Delta eBMGR.

Vendor API

BACER reads the BMS through the vendor's API. Used where BACnet/IP cannot be exposed and MS/TP routing is not practical.

Last resort

Scheduled CSV extract

The BMS or EMS server sends scheduled exports on a timetable. Lower fidelity, fewer points and more lag than the live paths, so it is used only where no live path is available.

Compare

Which path suits your site

PathLive dataBACER on siteBest for
BACnet/IPYesYesSites already exposing BACnet/IP
BACnet MS/TP routed to IPYesYesEstates running MS/TP on the controller side
Vendor APIYesYesWhere BACnet cannot be exposed
Scheduled CSV extractNoTypically not requiredSites with no live path available

Live paths deliver higher fidelity and lower lag than scheduled extracts, which is why CSV is used only where no live path is available.

Protocol

What is BACnet, and why it matters

BACnet (Building Automation and Control networks) is the data communication protocol developed by ASHRAE to let building automation devices from different manufacturers talk to each other. It is the most widely deployed building communication protocol in the world, with global market share above 60%.

BACnet/IP

Runs over the IP network. PEAK reads this directly, with no hardware on site beyond the BACER collector.

BACnet MS/TP

Runs over RS-485 serial, typically between field controllers. It needs routing to BACnet/IP before PEAK can read it, and most estates already have a router doing this.

A system described as BACnet compatible may be running MS/TP only, so it is worth confirming which form is in use before assuming an integration path. Where a BMS network spans several IP subnets or VLANs, PEAK works with whichever arrangement the site already has: an existing BBMD forwarding broadcasts between subnets, BACER registered as a foreign device, or BACER placed on the same subnet as the devices it reads.

Data sources

Beyond the BMS

The BMS is one source. PEAK consolidates everything the building already produces into a single portfolio dataset.

Meters and sub-meters

Electricity, gas and water feeds, including interval and sub-meter data.

IoT sensors

Temperature, humidity and equipment sensors already installed on site.

Lifts and plant

Lift controllers, HVAC plant and other equipment feeds available on the network.

Weather data

Local conditions used to normalise performance and separate weather effects from faults.

PEAK runs across more than 600 commercial buildings in 11 countries and four continents, with the largest deployments in the United States, the United Kingdom, Ireland, Australia and New Zealand.

Supported systems

Building management systems PEAK reads

PEAK connects to the systems already installed across commercial estates. The list below covers platforms connected in production today.

Trend

Tridium Niagara

Schneider Electric

Honeywell

Siemens

Johnson Controls

Distech Controls

Delta Controls

Alerton

Automated Logic

Frequently asked questions

Common questions about connecting PEAK to an existing building management system

Does PEAK replace my BMS?

No. PEAK reads data from your existing BMS and analyses it. It does not control plant, does not change your control strategy, and does not require any part of your controls to be replaced.

Which BMS platforms does PEAK work with?

PEAK is vendor-agnostic. Rather than supporting a fixed list of brands, it connects through BACnet/IP, routed BACnet MS/TP, vendor APIs or scheduled CSV extracts, which covers the large majority of commercial building management systems in use today.

Do I need to install new sensors or field devices?

No. PEAK uses the data your BMS, meters and sub-meters already produce. The only hardware on site is the BACER collector, which reads the network.

Can PEAK connect to a building running BACnet MS/TP only?

Yes, once the MS/TP trunks are routed to BACnet/IP. Many estates already have a suitable router in place. Where one is not installed, adding it is normally a BMS contractor task rather than an IT change.

What does the BMS contractor need to do?

Confirm which integration path the site supports, make BACnet/IP visible to the BACER install point, and confirm device IDs and network numbers are unique across the network. Full contractor guidance is on the PEAK Help Centre.

Still have questions?

Can’t find the answer you’re looking for? Please check our support page or chat to our friendly team.